Motor Starter Supplier Schneider of Schneider in Aurangabad-Bihar, Akola, Baramati, Pune

Standard Sales Corporation

NAN 0 Votes
Send Enquiry       Write a Review

Motor Starter

Range

Voltage rating- 240 V, 415 V, 360 V, 220 V

HP rating- 0.125 HP, 0.25 HP, 0.5 HP, 0.75 HP, 1 HP, 1.25 HP, 1.5 HP, 1.75 HP, 2 HP, 2.5 HP, 3 HP, 4 HP, 5 HP, 0.05 HP, 0.1 HP, 0.15 HP, 0.2 HP, 6 HP, 7.5 HP, 10 HP, 10.5 HP, 15 HP, 17.5 HP, 20 HP, 25 HP, 30 HP, 35 HP, 40 HP, 45 HP, 12.5 HP, 50 HP, 60 HP, 65 HP, 70 HP, 75 HP, 90 HP, 100 HP, 125 HP, 150 HP, 175 HP

BrandsSchneider
More Details

Star Delta Starter-

-TSD/A, Automatic 3 Phase (7.5 - 400 HP)

Motor HP Rating- 7.5 HP, 10 HP, 12.5 HP, 15 HP, 20 HP, 25 HP, 30 HP, 35 HP, 40 HP, 50 HP, 60 HP, 75 HP, 100 HP, 125 HP, 150 HP, 200 HP, 250 HP, 400 HP


DOL Starter-

TDL, Automatic 1 Phase (0.17 - 3 HP)

Motor Power HP Rating- 0.17 HP, 0.33 HP, 0.5 HP, 1 HP, 1.5 HP, 2 HP, 3 HP

TDL, Automatic 3 Phase (0.05 - 125 HP)

Motor Power HP Rating- 0.05 HP, 0.125 HP, 0.17 HP, 0.25 HP, 0.33 HP, 0.5, 0.75 HP, 1 HP, 1.5 HP, 2 HP, 3 HP, 5 HP, 7.5 HP, 10 HP, 12.5 HP, 15 HP, 17.5 HP, 20 HP, 25 HP, 30 HP, 35 HP, 40 HP, 50 HP, 60 HP, 75 HP, 100 HP, 125 HP

TRS, Automatic Reversing 3 Phase (3 - 20 HP)

Motor Power HP Rating- 3 HP, 5 HP, 7.5 HP, 10 HP, 12.5 HP, 15 HP, 17.5 HP, 20 HP


TeSys H - Ultra-compact starters-

Ratings -
2.4 A 400 V AC53a - 6.5 A 400 V AC53a 

control voltages- 24 V DC - 110 V / 230 V AC

terminal types- Screw clamps, Spring

Safe Torque Off embedded - SIL3 according to IEC61508-1 - Ple according to ISO13849-1

ATEX - As associated devices motor protection

functions-
Forward running
Reverse running
Overload protection


TeSys U - Advanced Motor Starter-

Total Coordinated Starter – 3 functions in a single device 

Direct connectivity to Modbus / Probus / CANopen /   DeviceNet

Higher switching life - 15Million operations, 2Million AC-43  electrical life 

Breaking capacity upto 130kA

Compact Starter

Description-

Power Bases for Non-Reversing D.O.L. Starter-12 A, 32 A

Rating at 440 V kW- upto 5.5 kw, upto 15 kw


Tesys T Motor Management Systems-

TeSys T covers all load monitoring and protection needs from feeders to critical process automation. The equipment is protected, while advanced diagnostics, statistics, and alarms help in anticipating unexpected production halts and minimize downtime. TeSys T is compact and a natural for control panels with IEC or NEMA standards. In addition, the system’s connectivity and access to real-time data provides key information to enhance the operation and safety of the process while improving effciency.

Tesys T Controller- Intelligent motor controller for 1P/3P Motors with built in CT up to 100 Amps with accurate monitoring and protection functions, 6DI, 4DO, 1CBCT input, 1 Temperature probe


Protection Functions

Thermal overload 

Phase imbalance and phase overloads 

Temperature monitoring via probes 

Phase reversal 

Ground fault detection 

Long start and Jam protection 

Load shedding 

Load fluctuations 

power factor monitoring


Monitoring Functions-

Phase and average current 

Line to Line and average voltage 

Motor temperature, ground current 

Active and Reactive Energy 

Frequency & Power Factor 

Detailed Fault history 

Fault counts 

motor statistics


Control Functions-

Local / Remote / HMI control 

Predefined programs for DOL, RDOL, Star-delta, two-speed starters

Applications-

Domestic pump sets, Air conditioners, Garage compressors, Wet Grinders, Domestic flour mills, Exhaust Fans, Sewing machines, Refrigerators, Washing machines, Desert coolers, Bottle Coolers, Floor polishers, Machine tools, Flour Mill & Agro Machinery



Not getting what you want ?? Please Let Us Know What You Want WhatsApp 8600391133